Specification
Packing size | 37×28×36cm/14.57×11.02×14.17inches |
Packaging weight | 4KG |
Voltage | 100V-240V |
Power supply | AC/DC dual-purpose |
Display | 12.1inches TFT display |
Standard parameters | ECG/RESP/NIBP/SPO2/TEMP/PR |
Warranty | 1year |
Product Features

Six Major Monitoring
ECG monitors cardiac electrical activity, RESP records respiratory rate, NIBP measures blood pressure non-invasively, SPO₂ monitors blood oxygen status, TEMP monitors body temperature, and PR tracks pulse rate. These six functions comprehensively cover core vital signs, enabling medical staff to capture changes in patients’ circulation, respiration, and other states in real time, providing accurate monitoring data to support clinical decision-making.

Multiple Parameters Displayed on the Same Screen
The multi-parameter same-screen display function allows medical staff to intuitively view key vital signs data such as electrocardiogram, respiration, blood pressure, and blood oxygen on the same interface without frequently switching interfaces. They can quickly and comprehensively grasp the patient’s status, improve monitoring efficiency in emergency, surgery, monitoring and other scenarios, and help to make timely judgments on the condition.

Print Function
It can print ECG waveforms, blood pressure, blood oxygen and other parameters and trend charts in real time/on demand, making it convenient for medical staff to immediately analyze the condition and mark diagnosis and treatment nodes. It can also archive medical records or be used for referral and handover, providing data support for diagnosis and treatment and ensuring continuity.

Intelligent Alarm System
The intelligent alarm function can monitor vital signs such as ECG, respiration, and blood pressure in real time, and quickly alarm when any parameters are abnormal. This helps medical staff to promptly detect patient abnormalities in scenarios such as rescue, surgery, and monitoring, saving time for treatment and improving the safety and timeliness of monitoring.

Easy to Operate
One-touch monitoring starts quickly and efficiently, and the intelligent shuttle knob reduces the learning curve. Whether you are an experienced medical veteran or a novice using the device, you can easily get started and efficiently obtain patient vital sign data in scenarios such as emergency treatment and surgery.

12.1-inch High-resolution Color TFT Display
The 12.1-inch high-resolution color TFT display clearly displays vital signs data such as ECG waveforms and SPO2 blood oxygenation curves. Its multi-mode adaptability supports monitoring, surgery, and diagnostic scenarios, enabling medical staff to quickly read and accurately capture details, providing an intuitive basis for clinical monitoring and judgment.

Independent Accessories Management Cabinet
The independent accessory management cabinet can store monitoring accessories in an orderly manner to prevent loss or clutter, allowing medical staff to quickly access them in scenarios such as emergency treatment and surgery. It also helps to standardize the storage and maintenance of equipment and accessories, improving ease of use and management efficiency.

Built-in Rechargeable Lithium Battery
The built-in rechargeable lithium battery automatically charges to full capacity when connected to AC power. If the device’s network power is lost, the monitor seamlessly switches to battery power to keep the device operational. Once fully charged, the monitor can operate for approximately 4 hours.
Application Scenarios

Tertiary Hospitals
For hospitalized patients, especially severe or postoperative ones, it monitors ECGand other vital signs in real time to help medical staff promptly grasp their condition changes.

Operating Room
During surgery, it tracks surgical patients’ vital signs throughout the process to provide data support for the safe conduct of operations.

Dental Hospital
In dental hospitals, it can monitor patients’ blood oxygen, pulse rate, and other vital signs during dental treatment to respond to possible emergencies.

Ambulance
In ambulances, it continuously monitors patients’ vital signs during transfer, offering key data for pre-hospital first aid and subsequent diagnosis and treatment connection.
Product Detail


Sensor Socket
TEMP1、TEMP2 | Surface temperature probe socket |
SPO2 | Oxygen probe socket |
ECG | ECG socket |
NIBP | Blood pressure socket |
IBP1、IBP2 | Invasive blood pressure (not available in this monitor) |

Function Button Area Identification and Operation Instructions
Serial number | Function | Functional Description |
① | switch button | Press this button to turn on the device, long press this button to turn off the device |
② | AC power indicator | When the monitor is connected to AC power via the power supply, the indicator light is yellow. |
③ | Battery power indicator | The indicator light is yellow when the monitor has no AC power and is powered by the built-in battery. |
④ | Alarm silence | Can turn off all sounds |
⑤ | Alarm pause | Stop the alarm and start a 2-minute countdown (you choose the time) |
⑥ | Freeze(or thaw)/Real-time recording | Press this button : freeze (or thaw) the waveform. Press this button long : start recording the real-time output. If real-time recording is in progress, either short or long press this key to stop real-time recording. |
⑦ | Start (stop) measuring | Press this button: start (or stop) the air pump, start (or end) non-invasive blood pressure measurement. |
⑧ | Press this button : start (or stop) print. (this monitor does not have this function) | |
⑨ | Menu | Press this button to pop up menu options . |
⑩ | Knob | The knob moves the cursor (select box) to select the option on the menu or the soft button on the screen ; press the knob to confirm the current option. |
Packing List

1. Main unit
2. SPO2 sensor
3. Temperature sensor
4.ECG lead wire
5. Electrode plate refusal×5
6. Ground cable
7. Power cable
8. NIBP extension tube
9. NIBP cuff
10. Instruction manual (CD)
Note:The standard version is for adults. If you need to change to children’s or newborn models, please contact customer service for notes when placing an order.
Product Parameters
ECG
Lead Mode | 5 Leads (I, II, I1I, AVR, AVL,AVF, V) |
Gain | 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV |
Heart Rate | 15-300 BPM(Adult); 15-350 BPM(Neonatal) |
Resolution | 1BPM |
Accuracy | ±1% |
Sensitivity | >200 uV(Peak to peak) |
ST measurement range | -2.0~+2.0mV |
Accuracy | -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater |
Sweep speed | 12.5 mm/s, 25mm/s,50mm/s |
Bandwidth | Diagnostic: 0.05~130 Hz Monitor:0.5~40 Hz Surgery:1~20 Hz |
SPO2
Measuring Range | 0~100% |
Resolution | 1% |
Accuracy | 70%~ 100% (±2 %) |
Pulse Rate | 20-250 BPM |
Resolution | 1BPM |
Accuracy | ±3 BPM |
NIBP
Mode | Adult Mode | Pediatric Mode | Neonatal Mode |
SYS | 40~280 mmHg | 40~220 mmHg | 40~135 mmHg |
DIA | 10~225 mmHg | 10~160 mmHg | 10~100 mmHg |
MEAN | 20~240 mmHg | 20 ~170 mmHg | 20~110 mmHg |
TEMP
Measure and Alarm Range | 0~50C |
Resolution | 0.1C |
Accuracy | ±0.1C |
RESP
Method | Impedance between RA-LL or RALA |
Measurement Range | Adult: 10~ 120 BrPM Neonatal / Pediatric:7~150 BrPM |
Resolution | 1BrPM |
Accuracy | ±2 BrPM |
Installation of ECG Lead

Lead name | color | location |
RA(C) | white | (right arm) electrode is placed under the clavicle near the right shoulder. |
LA(N) | black | electrodes are placed under the clavicle, close to the left shoulder.Place it on the chest wall as shown above. |
RL(F) | green | (right leg) electrode is placed in the right lower abdomen. |
LL(R) | red | (left leg) electrode one placed in the left lower abdomen . |
V(L) | brown | electrodes are placed on the chest wall. |
Warning:In European standards, use of R、L、N、F、C for each lead,in the American standard for RA、 LA 、RL 、LL 、V
Placement of Chest Conductive Pole in Lead 5

Serial number | Location |
V1 | in the fourth intercostal space on the right sternum. |
V2 | in the fourth intercostal space on the left sternum. |
V3 | midway between V2 and V4. |
V4 | in the fifth intercostal space on the left midclavicular line. |
V5 | in the anterior row of the left axilla, at the same horizontal position as V4 |
V6 | in the left midaxillary line, at the same horizontal position as V4. |
V3R-V7R | on the right side of the chest wall, corresponding to the left side. |
VE | on the ridge of the xiphoid process. “V” will result in “V” electrode placement in one of the following locations. |
V7 | on the fifth rib in the left posterior axillary line. |
V7R | on the lower lateral side in the fifth intercostal space on the right posterior axillary line. |
FAQ
1. Most commonly used hospital cleaning fluids and non-corrosive detergents can be used, but please note that many must be diluted before use.
2. Avoid using alcohol-, ammonia-, or acetone-based detergents.
3. The monitor case and screen should be kept dust-free and can be cleaned with a soft velvet cloth or sponge dampened with detergent. When cleaning, be careful not to spill liquids on the instrument and ensure that no liquid enters the interior. The monitor’s side panel has various cable sockets; be careful when wiping to ensure that no water enters.
4. Do not use abrasive materials such as wire brushes or metal polishes, as these may damage the monitor panel and screen.
5. Do not immerse the monitor in liquids.
6. If the plugs of cables or accessories occasionally become wet, rinse with distilled or deionized water and allow to cool in an environment of 40°C to 80°C for at least 1 hour.
Before using the monitor, perform the following inspections:
1. Check for any mechanical damage;
2. Inspect all exposed wires, plug-in components, and accessories;
3. Check all instrument functions that may be used to monitor patients and ensure that the instrument is in good working condition.
If the patient’s skin feels uncomfortable, immediately wipe off the residual gel gently with warm water and avoid rubbing it hard. If redness is obvious, apply medical petroleum jelly or a mild skin protectant (make sure the patient has no history of allergies). Usually, the symptoms will be relieved in 1-2 days. If a rash or blisters occur, contact a dermatologist promptly for treatment.
Reviews
There are no reviews yet.